AMYB-5S20-DP7
Profibus DP Position Monitoring
FMYB-5S20-DP7
PMYB-5S20-DP7
SMYB-5S20-WP2
Profibus DP Position Monitoring
Moniteur VPCs with encapsulated Profibus interface cards adapt your on/off automated valves to an advanced Profibus DP valve network. The Profibus protocol was developed in 1989 by a group of factory automation suppliers.
Profibus-DP is a device level bus that supports both analog and discrete signals. Profibus-DP has widespread usage for such items as remote I/O systems, motor control centers, and variable speed drives. Profibus-DP communicates at speeds from 9.6 Kbps to 12 Mbps over distances from 100 to 1,200 meters.
Moniteur’s Advanced Profibus Platform Improves Reliability
The Network Card
A full function encapsulated network card includes the following benefits:
- Encapsulated electronics and position sensors ensure reliability in corrosive, humid and dirty environments.
- Hall effect position sensors designed for the card and provide optimum stability in areas of high vibration.
- Two transistor outputs each with an output of 4.8w @ 24VDC are available for your solenoid valves and allow many standard DC NAMUR valves to be used, avoiding special “low power” valves
- High visibility LEDs are located on-board for local indication of on -board sensors, auxiliary inputs, outputs and network state.
- Two additional inputs are optional for local pressure or temperature switches.
The Enclosure Platform
Moniteur’s platform is available in a wide variety of enclosure materials to match your hazardous or corrosive environment and is designed to provide long-term reliability.
- Housings in Aluminum or SuperTough Zytel
- Thermoplastic for General Purpose or Hazardous Areas
- Moniteur’s patented Loc-Ring Cam and Shaft Retention System ensures sensing accuracy and a multi-million cycle life of the physical platform.
- DIN 4-pin Female Micro or 5-pin Mini plug connectors can be fitted to the conduit entries of the enclosures to speed installation in general purpose areas.
- Moniteur’s industry-preferred indicator has a rated minimum life of 1,000,000 cycles. With indicators still in service after 9 million cycles, you’re assured of long-term reliability.
Profibus DP Technical Information
- Each network supports up to 32 devices per segment or 64 with repeaters
- Automatic baud rate up to 500K bit/sec.
- Up to 1000m maximum trunk length w/o repeaters
- Supports both discrete and analog signals
- I/O modules allow connection of conventional analog and discrete devices
- Interfaces available for many variable speed drives, motor control centers, and field devices
- Supports 32 devices per segment, 62 with repeaters
- Simple integration of new devices to an existing network
- Supports mono-master and multi-master systems
Intelligent Part Number System
A | M | Y | B | - | 5 | S | 2 | 0 | - | DP7 |
1 | 2 | 3 | 4 | - | 5 | 6 | 7 | 8 |
1 - Enclosure Type | 4 - Bearing | ||
Ex-proof Nema 7,9 Aluminum | A | Bronze | B |
General Purpose Aluminum Nema 4 | F | 303 Stainless | S |
Zytel Thermolastic Nema 4 | R | 5 - Shaft | |
2 - Cover | Standard 303 SS | 1 | |
With Moniteur | M | Standard 316 SS | 3 |
Flat Cover | F | NAMUR 303 SS | 5 |
3 - Moniteur | NAMUR 316 SS | 7 | |
No Indicator | N | LONG NAMUR 303 SS | E |
Black / Yellow | Y | LONG NAMUR 316 SS | G |
3-way path O | O | 6 - Switch Type | |
3-way path T | T | On Board Hall Effect Sensors | S |
3-way path F | F | 7 - Sensor Quantity | 2 |
4-way path S | S | 2 | 2 |
180 degree T | 1 | 8 - Conduit | |
Green / White | G | (2) F 3/4" NPT (A) | 0 |
Red / White | R | (2) F 3/4" + (1) F 1/2" NPT (A) | 6 |
Blue / White | B | (2) F 1/2" NPT (F, R) | 0 |
Green / Red | A | (3) F 1/2" NPT (F, R) | 6 |
Red / Green | C | Network Card | |
Profibus DP, 2 Transistor Outputs | 0 |
Additional Advantages of In-Plant Networking
Drastically Reduced Installation Costs – Wiring and installation time are reduced, yielding a cost saving up to 40% versus conventional methods.
Reduced Maintenance Costs and Increased System Reliability – Components require less maintenance and are designed to work “one way” only.
Built-in diagnostic functions allow components to be continuously monitored.
Faster Start-Up – Set-up is simpler and diagnostic functions speed troubleshooting.
Simplified Plant Wiring – Automated valves can be inter-connected in any configuration. Utilizing only 2 or 4 wires eliminates wiring “spaghetti” of older schemes.
- Benefits
Moniteur’s Advanced Profibus Platform Improves Reliability
The Network Card
A full function encapsulated network card includes the following benefits:
- Encapsulated electronics and position sensors ensure reliability in corrosive, humid and dirty environments.
- Hall effect position sensors designed for the card and provide optimum stability in areas of high vibration.
- Two transistor outputs each with an output of 4.8w @ 24VDC are available for your solenoid valves and allow many standard DC NAMUR valves to be used, avoiding special “low power” valves
- High visibility LEDs are located on-board for local indication of on -board sensors, auxiliary inputs, outputs and network state.
- Two additional inputs are optional for local pressure or temperature switches.
The Enclosure Platform
Moniteur’s platform is available in a wide variety of enclosure materials to match your hazardous or corrosive environment and is designed to provide long-term reliability.
- Housings in Aluminum or SuperTough Zytel
- Thermoplastic for General Purpose or Hazardous Areas
- Moniteur’s patented Loc-Ring Cam and Shaft Retention System ensures sensing accuracy and a multi-million cycle life of the physical platform.
- DIN 4-pin Female Micro or 5-pin Mini plug connectors can be fitted to the conduit entries of the enclosures to speed installation in general purpose areas.
- Moniteur’s industry-preferred indicator has a rated minimum life of 1,000,000 cycles. With indicators still in service after 9 million cycles, you’re assured of long-term reliability.
- Technical Information
Profibus DP Technical Information
- Each network supports up to 32 devices per segment or 64 with repeaters
- Automatic baud rate up to 500K bit/sec.
- Up to 1000m maximum trunk length w/o repeaters
- Supports both discrete and analog signals
- I/O modules allow connection of conventional analog and discrete devices
- Interfaces available for many variable speed drives, motor control centers, and field devices
- Supports 32 devices per segment, 62 with repeaters
- Simple integration of new devices to an existing network
- Supports mono-master and multi-master systems
- Part Numbers
Intelligent Part Number System
A M Y B - 5 S 2 0 - DP7 1 2 3 4 - 5 6 7 8 1 - Enclosure Type 4 - Bearing Ex-proof Nema 7,9 Aluminum A Bronze B General Purpose Aluminum Nema 4 F 303 Stainless S Zytel Thermolastic Nema 4 R 5 - Shaft 2 - Cover Standard 303 SS 1 With Moniteur M Standard 316 SS 3 Flat Cover F NAMUR 303 SS 5 3 - Moniteur NAMUR 316 SS 7 No Indicator N LONG NAMUR 303 SS E Black / Yellow Y LONG NAMUR 316 SS G 3-way path O O 6 - Switch Type 3-way path T T On Board Hall Effect Sensors S 3-way path F F 7 - Sensor Quantity 2 4-way path S S 2 2 180 degree T 1 8 - Conduit Green / White G (2) F 3/4" NPT (A) 0 Red / White R (2) F 3/4" + (1) F 1/2" NPT (A) 6 Blue / White B (2) F 1/2" NPT (F, R) 0 Green / Red A (3) F 1/2" NPT (F, R) 6 Red / Green C Network Card Profibus DP, 2 Transistor Outputs 0 - Additional Advantages
Additional Advantages of In-Plant Networking
Drastically Reduced Installation Costs – Wiring and installation time are reduced, yielding a cost saving up to 40% versus conventional methods.
Reduced Maintenance Costs and Increased System Reliability – Components require less maintenance and are designed to work “one way” only.
Built-in diagnostic functions allow components to be continuously monitored.
Faster Start-Up – Set-up is simpler and diagnostic functions speed troubleshooting.
Simplified Plant Wiring – Automated valves can be inter-connected in any configuration. Utilizing only 2 or 4 wires eliminates wiring “spaghetti” of older schemes.
- Visual Indicator
- Documents
- 8Rotary Position Solutions
- 3Linear Position Solutions
- 6Positioners
- 4Networking
- 65Brackets Kits
- 3Spare Parts
- 16Resources